 | SERVICE DETAILS| PDF File | DWG File | Standard No. | Issue Date | Title/Description | Latest Approval Date |  |  | W1.1 | 11/03/93 | 5/8", 3/4" and 1" Service Detail | 10/11 |  |  | W1.2 | 11/03/93 | 1-1/2" and 2" Service Detail | 10/11 |  |  | W1.3 | 11/03/93 | 1" Fire Service with 5/8", 3/4" and 1" Domestic Service | 10/11 |  |  | W1.4 | 11/03/93 | 3" Domestic Service | 10/11 |  |  | W1.5 | 11/03/93 | 4" and Larger Domestic Services | 10/11 | | | W1.6 | 01/14/10 | (Not Used) | | | | W1.7 | 01/14/10 | (Not Used) | 10/11 |  |  | W1.8 | 11/03/93 | 1-1/2" and 2" Service Detail for Commercial Combination Domestic and Irrigation Services | 10/11 |  |  | W1.9 | 5/29/96 | 2" ABOVEGROUND FIRE SERVICE WITH DOUBLE CHECK DETECTOR ASSEMBLY | 05/12 | | | W1.10 | 01/14/10 | (Not Used) | 10/11 |  |  | W1.11 | 06/17/96 | 5/8", 3/4" and 1" Combination Domestic and Irrigation Service Detail | 10/11 |  |  | W1.12 | 06/25/96 | 3" Combination Domestic and 3”, 2”, or 1-1/2” Irrigation Service Detail | 10/11 |  |  | W1.13 | 05/29/96 | 4" and Larger Combination Domestic and Irrigation Service Detail | 10/11 |  |  | W1.14 | 02/13/99 | 4" and Larger Aboveground Fire Service with Double Check Detector Check Assembly | 10/11 |  |  | W1.15 | 11/05/99 | Approved Water Meters | 10/11 |  |  | W1.16 | 08/25/04 | Service Abandonment Detail | 10/11 | | | W1.17 | 08/25/04 | (Not Used) | 01/12 |  |  | W1.18 | 08/25/04 | Special Design Detail for 1-1/2” and 2” Services | 10/11 | | | W1.19 | 08/25/04 | (Not Used) | 10/11 | | | W1.20 | 08/25/04 | (Not Used) | 10/11 | FIRE HYDRANTS| PDF File | DWG File | Standard No. | Issue Date | Title/Description | Latest Approval Date |  |  | W2.1 | 11/03/93 | Typical Pipe and Fire Hydrant Layout (Alignment) | 10/11 |  |  | W2.2 | 11/03/93 | 6" Fire Hydrant Installation | 10/11 |  |  | W2.3 | 08/22/08 | Manual Blow Off Assembly With 6" Fire Hydrant Installation | 10/11 | VALVE ASSEMBLIES| PDF File | DWG File | Standard No. | Issue Date | Title/Description | Latest Approval Date |  |  | W3.1 | 11/03/93 | Typical Gate Valve Installation | 10/11 |  |  | W3.2 | 11/03/93 | Typical Butterfly Valve Installation | 10/11 |  |  | W3.3 | 08/25/04 | Typical Valve Can Installation | 10/11 | | | W3.4 | 01/14/10 | (Not Used) | 10/11 |  |  | W3.5 | 08/17/95 | Tapping Detail for 4" and Larger Developer-Installed Mains | 10/11 |  |  | W3.5A | 09/27/09 | Tapping Detail for 4" and Larger Contractor-Installed Mains | 10/11 |  |  | W3.6 | 02/12/02 | System Split Valve Bypass and Transmission Main Valve Installation | 10/11 |  |  | W3.7 | 08/25/04 | Excavation for Hot Taps | 10/11 |  |  | W3.8 | 10/22/07 | Above ground pressure reducing station | 10/11 |  |  | W3.9 | 10/26/07 | Below ground pressure reducing station | 10/11 | BACKFLOW PREVENTION| PDF File | DWG File | Standard No. | Issue Date | Title/Description | Latest Approval Date |  |  | W4.1 | 11/03/93 | Typical Installation of Reduced Pressure Principle Backflow Prevention Assembly | 02/12 | | | W4.2 | 12/16/09 | (Not Used) | 10/11 |  |  | W4.3 | 11/03/93 | 4" through 10" Double Check Detector Check Valve Assembly | 10/11 |  |  | W4.4 | 08/25/04 | Intertie to Neighboring Agencies Below Grade | 02/12 |  |  | W4.5 | 08/25/04 | Intertie to Neighboring Agencies Above Grade | 10/11 |  |  | W4.6 | 05/10/06 | Temporary Connection between Public System and Private Water System (Sheet 1) | 10/11 |  |  | W4.6 | 05/10/06 | Temporary Connection between Public System and Private Water System (Sheet 2) | 10/11 |  |  | W4.7 | 03/30/09 | Intertie to Neighboring Agencies Above Grade | 10/11 | TRENCHING| PDF File | DWG File | Standard No. | Issue Date | Title/Description | Latest Approval Date |  |  | W5.1 | 08/25/04 | Trench, Backfill, and Pavement Replacement Detail | 10/11 |  |  | W5.1A | 05/25/10 | Trench, Backfill and Pavement Replacement Detail for Water Utility Installation, Maintenance, and Repair (Supplement to W5.1) | 10/11 |  |  | W5.2 | 08/25/04 | Structural Support at Crossing | 10/11 | MISCELLANEOUS| PDF File | DWG File | Standard No. | Issue Date | Title/Description | Latest Approval Date |  |  | W6.1 | 11/03/93 | Water Sampling Station | 10/11 |  |  | W6.2 | 11/03/93 | Vertical Control Monument Detail | 10/11 |  |  | W6.3 | 11/03/93 | Blue Dot Pavement Markers and Fire Hydrant Marking (Sheet 1) | 10/11 |  |  | W6.3 | 11/03/93 | Blue Dot Pavement Markers and Fire Hydrant Marking (Sheet 2) | 10/11 |  |  | W6.4 | 11/03/93 | Restrained Joint Detail | 10/11 |  |  | W6.4A | 02/01/04 | Thrust Block Installation | 10/11 |  |  | W6.5 | 05/06/10 | Meter Removal Associated with Water Main Abandonment for Structures Using Water Service as Primary Electrical Ground | 10/11 |  |  | W6.6 | 11/03/93 | Field Staking for New Water Facilities | 10/11 |  |  | W6.7 | 03/01/94 | 2" Chlorination and Flushing Port | 10/11 |  |  | W6.8 | 06/01/10 | 2" Automatic Blow Off Detail | 10/11 |  |  | W6.9 | 12/06/96 | 4" through 16" Vertical Offset of Existing D.I., C.I., or A.C. Pipe | 10/11 |  |  | W6.9A | 08/25/04 | 4” through 16” Vertical Offset of Existing D.I., C.I., A.C., or Steel Pipe | 10/11 |  |  | W6.10 | 04/09/97 | 4" through 16" Vertical Offset of Existing Steel Pipe | 10/11 |  |  | W6.10A | 10/11/11 | Steel Pipe Buttstrap | 10/11 |  |  | W6.11 | 12/17/97 | 4" through 16" In-Line Thrust Block for Ductile Iron Pipe | 10/11 |  |  | W6.12A | 08/01/99 | Wrought Iron Fence and Gate Detail | 10/11 |  |  | W6.12B | 08/01/99 | Wrought Iron Drive Swing Gate Detail | 10/11 |  |  | W6.12C | 08/11/09 | Wrought Iron Drive Swing Gate Operator Detail | 10/11 |  |  | W6.13 | 09/02/10 | Fire Hydrant, Valve, and Tee Removal Detail | 10/11 |  |  | W6.14 | 02/23/00 | Water and Sewer Separation Standards | 02/12 | | | W6.15 | 01/14/10 | (Not Used) | 10/11 | | | W6.16 | 11/05/99 | (Not Used) | 10/11 | | | W6.16A | 01/14/10 | (Not Used) | 10/11 |  |  | W6.17 | 08/25/04 | Casing Assembly Detail | 10/11 |  |  | W6.18 | 08/25/04 | Manual Blow Off Assembly and Cover Detail | 10/11 |  |  | W6.19 | 08/25/04 | Pipe Penetration | 10/11 |  |  | W6.20 | 08/25/04 | Single Door Access Hatch | 10/11 |  |  | W6.21 | 08/25/04 | Double Door Access Hatch | 10/11 |  |  | W6.22 | 08/25/04 | Ladder Installation Details | 10/11 |  |  | W6.23 | 08/25/04 | Concrete Masonry Fence Detail (Not To Be Used For Retaining Earth) | 10/11 |  |  | W6.24 | 08/25/04 | Detail for 4”–16” Steel Pipe, Cut and Plug Existing Water Main | 10/11 |  |  | W6.25 | 08/25/04 | Detail for 4”-16” C.I.P. or D.I.P., Cut and Plug Existing Water Main | 10/11 | | | W6.26 | 08/25/04 | (Not Used) | 10/11 |  |  | W6.27 | 11/04/05 | Restrained Flexible Coupling Restraint (Sheet 1) | 10/11 |  |  | W6.27 | 11/04/05 | Restrained Flexible Coupling Restraint (Sheet 2) | 10/11 |  |  | W6.28 | 11/04/05 | Pipe Support and Under Flange Support (Sheet 1) | 10/11 |  |  | W6.28 | 11/04/05 | Pipe Support and Under Flange Support (Sheet 2) | 10/11 |  |  | W6.29 | 11/04/05 | Air Vent for U.G. Structures | 10/11 |  |  | W6.30 | 11/04/05 | Sum Grate Details | 10/11 |  |  | W6.31 | 11/04/05 | Drain Connection Detail | 10/11 |  |  | W6.32 | 11/04/05 | Pressure Gauge Connection Detail | 10/11 |  |  | W6.33 | 11/04/05 | PVC Wall Insert | 10/11 |  |  | W6.34 | 11/16/05 | Construction Sign | 10/11 |  |  | W6.35 | 11/04/05 | Customer Notification Door Hanger | 10/11 |  |  | W6.36 | 09/05/06 | Underground Facility Marker | 10/11 |  |  | W6.37 | 10/25/07 | Removable protective bollard | 10/11 |  |  | W6.38 | 02/26/08 | Outdoor Light Pole | 10/11 |  |  | W6.38A | 10/11/11 | Floodlight Detail | 02/12 |  |  | W6.39A | 10/11/11 | Curb and Cutter Crossing Config. 12" and Larger Pipelines | 10/11 |  |  | W6.39B | 10/11/11 | Curb and Cutter Crossing Config. 3" Through 8" Pipelines | 10/11 |  |  | W6.39C | 10/11/11 | Curb and Cutter Crossing Config. 2" and Smaller Pipelines | 10/11 | AIR VALVES| PDF File | DWG File | Standard No. | Issue Date | Title/Description | Latest Approval Date |  |  | W7.1 | 12/21/93 | 1" and 2" Air Release Valves, 2" Vacuum Valve, and 2" Combination Valve | 10/11 |  |  | W7.2 | 02/28/94 | 3" and Larger Combination Air Vacuum and Release Valve and Air Vacuum Valve | 10/11 |  |  | W7.3 | 09/10/01 | 1" Combination Air Vacuum and Release Valve and Flushing Port for Cul-De-Sacs | 10/11 |  |  | W7.4 | 08/25/04 | 1” Air Release Valve in Bridge Structure | 10/11 |  |  | W7.5 | 08/25/04 | Low Cover Installation for 1” and 2” Air Release Valves, Vacuum Valve, and Combination Valve | 10/11 |  |  | W7.6 | 11/01/05 | Steel Enclosure for Air Valve Assembly | 10/11 | GEOTHERMAL| PDF File | DWG File | Standard No. | Issue Date | Title/Description | Latest Approval Date |  |  | W8.1 | 09/29/05 | Typical Geothermal Services | 10/11 | WELLS| PDF File | DWG File | Standard No. | Issue Date | Title/Description | Latest Approval Date |  |  | W9.1 | 08/25/04 | Well Head Completion | 10/11 |  |  | W9.2 | 04/20/09 | Typical Vertical Turbine Section | 10/11 |  |  | W9.3 | 08/25/04 | Typical Submersible Pump Well Detail | 10/11 | BOOSTERS| PDF File | DWG File | Standard No. | Issue Date | Title/Description | Latest Approval Date |  |  | W10.1 | 08/25/04 | Typical Booster Station Plan | 10/11 |  |  | W10.2 | 08/25/04 | Typical Booster Station Section | 10/11 | ELECTRICAL| PDF File | DWG File | Standard No. | Issue Date | Title/Description | Latest Approval Date |  |  | W11.1 | 06/27/05 | Three Line and Control Square D at S48 Soft Starter Pumps/Wells | 10/11 |  |  | W11.2 | 06/27/05 | Three Line and Control Drawing Allen Bradley Bulletin Soft Starter Pumps/Wells | 10/11 |  |  | W11.3 | 06/27/05 | Three Line and Control Drawing Culter Hammer IT S801 Soft Starter Pumps/Wells | 10/11 |  |  | W11.4 | 06/27/05 | Internal Components Layout | 10/11 |  |  | W11.5 | 06/27/05 | Internal Components Layout | 10/11 |  |  | W11.6 | 06/27/05 | One Line Drawing | 10/11 |  |  | W11.7 | 06/27/05 | Legend and Legend Plate Detail | 10/11 |  |  | W11.8 | 08/25/05 | Remote SCADA Master RTU | 10/11 |  |  | W11.9 | 10/24/05 | Emergency Power Panel Detail (Sheet 1) | 10/11 |  |  | W11.9 | 10/24/05 | Emergency Power Panel Detail (Sheet 2) | 10/11 |  |  | W11.10 | 03/16/06 | Emergency Generators Power Connection | 10/11 |  |  | W11.11 | 03/16/06 | Emergency Generators Type 3R Wiring Trough | 10/11 |
These documents are in Adobe
PDF form. Adobe Acrobat Reader is needed to view these files. If you do not have
Adobe Acrobat Reader you can get it free at
www.adobe.com

|  |
|
We're Social: